BTEN AIRCOOL

Wednesday, 10 January 2018

THE CENTRAL AIR CONDITIONING PLANT

 Btenaircool Services     January 10, 2018     No comments   

 air conditioning machine whose complete water cooled condensing unit :-.eluding evaporator is located in the basement and the conditioned air is forced by a blower into the various rooms through ducts. In winter for heating electrical heating strips are used in front of blower.
The blower throws air through these heating strips and heats the rooms.
In another indirect air conditioning system water is chilled in a chiller by a water cooled condensing unit fitted in a room. This chilled water is circulated through many
pipe coils fitted in various rooms.
The air is forced through these chilled water pipe coils into the rooms to be cooled.

  • Share This:  
  •  Facebook
  •  Twitter
  •  Google+
  •  Stumble
  •  Digg
Email ThisBlogThis!Share to XShare to Facebook

Related Posts:

  • Types of a Compressor Centrifugal compressor. Reciprocating compressor. Rotary screw compressor. Scroll or spiral compressor.  Wobble or Swash plate compre… Read More
  • Float valve function  The liquid level falls below the normal level in the float housing, the float ball comes down pulls the needle from its seat and allows the liq… Read More
  • CONDENSER Condenser is a part in mechanical refrigeration system which condenses the gas above its critical pressure and below its critical temperature. To r… Read More
  • LAWS OF REFRIGERATION The laws upon which the theory of refrigeration is based and where they find their applications in refrigeration system. Heat can be converted into… Read More
  • Rotary Compressor main parts Main body. Eccentric shaft Suction service valve. Discharge valve plate  Discharge service valve. Discharge valve Cylinder or pum… Read More
Newer Post Older Post Home

0 comments:

Post a Comment

More Info

  • Formula for finding the piston displacement of a compressor
    Compressor can be calculated as follows:- Where:- V = Volume in cubic feet.  D = Diameter of cylinder in inches.  S = Length o...
  • Refrigerant pressure readings R-22, R-410A, R-290, R-417A
    R-22 Standing pressure              -                150 PSI Saction pressure                -                 60 TO 70 PSI Discha...
  • How to Identify Common / Start / Run on the t Compressor Terminal
    in 3 easy steps use the formula: - 1. common and start is equal to medium value 2. start and running is equal to high...
  • Refrigeration system?
                                                                          GAS FILTER                                             ...
  • Air conditioning problems
    We Take Care of all Air Conditioning Problems in Mumbai. We have more than 7 years experience of handling all types of air conditioning ...

Course Process

  • High side and Low side ?
  • Interview Questions
  • Lock Rotor Amps
  • Mechanical refrigeration
  • Refrigerant pressure readings
  • Refrigeration system
  • ServiceTool
  • Temperature-pressure
  • Voltage type relay
  • Wiring Diagram

Related Posts:

  • Gas charging ,R410A R22 R32 pressures, - HINDI
    This video is helping to know  identify the gas in the  air condition unit and what kinds of the pressure we will maintain to the ai...
  • Refrigerant pressure readings R-22, R-410A, R-290, R-417A
    R-22 Standing pressure              -                150 PSI Saction pressure                -                 60 TO 70 PSI Discha...
  • How to Identify Common / Start / Run on the t Compressor Terminal
    in 3 easy steps use the formula: - 1. common and start is equal to medium value 2. start and running is equal to high...
  • Formula for finding the piston displacement of a compressor
    Compressor can be calculated as follows:- Where:- V = Volume in cubic feet.  D = Diameter of cylinder in inches.  S = Length o...

Blog Archive

  • ►  2019 (1)
    • ►  January (1)
  • ▼  2018 (35)
    • ►  July (2)
    • ►  February (2)
    • ▼  January (31)
      • Rotary Compressors:-
      • Hermetic Compressors
      • Important Terms
      • How to wiring window air condition
      • Window air condition PCB board wiring
      • L R A ( Lock Rotor Amps ) HINDI
      • Gas charging ,R410A R22 R32 pressures, - HINDI
      • Formula for finding the piston displacement of a c...
      • LAWS OF REFRIGERATION
      • Float valve function
      • CONDENSER
      • Rotary Compressor main parts
      • Types of a Compressor
      • Lock Rotor Amps
      • Tube cutter
      • Voltage type relay work ?
      • Types of a relay
      • How to Identify Common / Start / Run on the t Comp...
      • RETROFITTING OF R 22 MACHINE WITH R427 A
      • R427 A
      • R410 A
      • Mechanical refrigeration system
      • FLOAT VALVE CONTROLS
      • CAPILLARY TUBE
      • THE CENTRAL AIR CONDITIONING PLANT
      • Split Air Conditioner Selection of place for insta...
      • Refrigeration system?
      • Ton AC sufficient foot room
      • Gas charging
      • Refrigerant pressure readings R-22, R-410A, R-290,...
      • What is R410a Refrigerant
  • ►  2017 (7)
    • ►  December (7)

ABOUT US

ABOUT US
Ramesh Kurup :- Hello friends welcome to our blog “ Bten aircool. This is Ramesh Kurup.I am a professional Air Conditioner technician. I work with Bten Aircool since 3 years. This company is located in Mumbai Maharashtra.

Featured post

Voltage type relay work ?

  • Privay Policy
  • Disclaimer
  • Contact Us

Copyright © 2025 BTEN AIRCOOL