BTEN AIRCOOL

  • About Us
  • Wiring Diagram
    • Window air condenser wiring
    • Outdoor unit wiring diagram
    • PCB Wiring
    • Compressor wiring diagram
  • Revision Test Papers
    • HINDI
    • ENGLISH
  • Home
  • Voltage type relay
    • Refrigerant pressure readings
    • Refrigerant pressure
    • Float valve
  • Refrigeration
    • high side and low side system?
    • Ton Of Refrigeration
    • Revision test paper
      • R410a Refrigerant
  • Rotor Amps
    • Tons conversion calculator
  • TEMPERATURE-PRESSURE
  • Contact Us
BTEN AIRCOOL

Thursday, 11 January 2018

R427 A

 Btenaircool Services     January 11, 2018     No comments   

This refrigerant has been prepared by mxing R32 +R125 + R143a + R134a in their mass percentages of 15 + 25 + 10 + 50 respectively. It belongs to HFC group of refrigerants. Its ODP is zero and GWP is 2000. It is neither toxic nor flammable. Therefore it comes under the safety class of Al. Its boiling point at atmospheric pressure is —42.7°C. It is mixable with polyolester oils. Therefore, after drawing out mineral or alkybenzene oil from the compressor, new polyolester (POE) oil should be charged. Mineral oil can also be used with R427A machine if an oil separator may be fitted with this machine. This refrigerant can be replaced in R22 refrigerant machine without making any special change.

  • Share This:  
  •  Facebook
  •  Twitter
  •  Google+
  •  Stumble
  •  Digg
Email ThisBlogThis!Share to XShare to Facebook

Related Posts:

  • Ton Of Refrigeration - HINDI … Read More
  • Lock Rotor Amps L R A ( Lock Rotor Amps ) If L R A Mansion in your compressor. How we know the ton of the  compressor:- ANS:- It's Simple put a formula … Read More
  • What is the meaning of BTU in air conditioners?(Q) What is "Ton of refrigeration" and how it has been derived ?  Ans. The refrigeration capacity of a machine is expressed in "Ton of refrigera… Read More
  • Mechanical refrigeration system  In mechanical refrigeration system, the vapours caused by a sudden change of liquid in metering device without gaining any heat is known as fla… Read More
  • Gas charging Gas charging ,R410A R22 R32 pressures, - HINDI … Read More
Newer Post Older Post Home

0 comments:

Post a Comment

More Info

  • Refrigerant pressure readings R-22, R-410A, R-290, R-417A
    R-22 Standing pressure              -                150 PSI Saction pressure                -                 60 TO 70 PSI Discha...
  • Lock Rotor Amps
    L R A ( Lock Rotor Amps ) If L R A Mansion in your compressor. How we know the ton of the  compressor:- ANS:- It's Simple p...
  • What is the high side and low side of the refrigeration system?
    Q. What are the parts which divide the refrigeration system into low pressure side and high pressure side ?  Ans. Refrigerant c...
  • Formula for finding the piston displacement of a compressor
    Compressor can be calculated as follows:- Where:- V = Volume in cubic feet.  D = Diameter of cylinder in inches.  S = Length o...
  • Types of a relay
    Three types of relay :-  Current coil or amperage type relay Potential or voltage type relay. Hot wire relay.          Relay ? ...

Course Process

  • High side and Low side ?
  • Interview Questions
  • Lock Rotor Amps
  • Mechanical refrigeration
  • Refrigerant pressure readings
  • Refrigeration system
  • ServiceTool
  • Temperature-pressure
  • Voltage type relay
  • Wiring Diagram

Related Posts:

  • Gas charging ,R410A R22 R32 pressures, - HINDI
    This video is helping to know  identify the gas in the  air condition unit and what kinds of the pressure we will maintain to the ai...
  • Refrigerant pressure readings R-22, R-410A, R-290, R-417A
    R-22 Standing pressure              -                150 PSI Saction pressure                -                 60 TO 70 PSI Discha...
  • How to Identify Common / Start / Run on the t Compressor Terminal
    in 3 easy steps use the formula: - 1. common and start is equal to medium value 2. start and running is equal to high...
  • Formula for finding the piston displacement of a compressor
    Compressor can be calculated as follows:- Where:- V = Volume in cubic feet.  D = Diameter of cylinder in inches.  S = Length o...

Blog Archive

  • ►  2019 (1)
    • ►  January (1)
  • ▼  2018 (35)
    • ►  July (2)
    • ►  February (2)
    • ▼  January (31)
      • Rotary Compressors:-
      • Hermetic Compressors
      • Important Terms
      • How to wiring window air condition
      • Window air condition PCB board wiring
      • L R A ( Lock Rotor Amps ) HINDI
      • Gas charging ,R410A R22 R32 pressures, - HINDI
      • Formula for finding the piston displacement of a c...
      • LAWS OF REFRIGERATION
      • Float valve function
      • CONDENSER
      • Rotary Compressor main parts
      • Types of a Compressor
      • Lock Rotor Amps
      • Tube cutter
      • Voltage type relay work ?
      • Types of a relay
      • How to Identify Common / Start / Run on the t Comp...
      • RETROFITTING OF R 22 MACHINE WITH R427 A
      • R427 A
      • R410 A
      • Mechanical refrigeration system
      • FLOAT VALVE CONTROLS
      • CAPILLARY TUBE
      • THE CENTRAL AIR CONDITIONING PLANT
      • Split Air Conditioner Selection of place for insta...
      • Refrigeration system?
      • Ton AC sufficient foot room
      • Gas charging
      • Refrigerant pressure readings R-22, R-410A, R-290,...
      • What is R410a Refrigerant
  • ►  2017 (7)
    • ►  December (7)

ABOUT US

ABOUT US
Ramesh Kurup :- Hello friends welcome to our blog “ Bten aircool. This is Ramesh Kurup.I am a professional Air Conditioner technician. I work with Bten Aircool since 3 years. This company is located in Mumbai Maharashtra.

Featured post

Voltage type relay work ?

  • Privay Policy
  • Disclaimer
  • Contact Us

Copyright © 2025 BTEN AIRCOOL