R410 A

 Btenaircool Services     January 11, 2018     No comments   

This refrigerant has been prepared by mixing R32 + R125 in equal quantity. It belongs to HFC group of refrigerants. Its ODP is zero and GWP is 1800. It is neither toxic nor flammable. Therefore it comes under the safety class of Al. Its boiling point at atmospheric pressure is —52.7°C. It is mixable with polyolester (POE) oil. As it catches the moisture rapidly from the air, therefore it may be noticed that it may not come in contact with air while charging it into the machine. This refrigerant was prepared for the replacement of R22 gas but due to its less cooling capacity and extremely high working pressures, it could not be successful. Therefore it has been used only in those machines which specially have been designed for this refrigerant.


  • Share This:  
  •  Facebook
  •  Twitter
  •  Google+
  •  Stumble
  •  Digg
Email ThisBlogThis!Share to XShare to Facebook

Related Posts:

  • Tube cutter Always hold the open end of the tube down when reaming or filing, so that metal chips may not go in side the tube.  Do not cut flat … Read More
  • Voltage type relay work ? S.No   Amperage type Relay Voltage type Relay   1.   It is used with split phase hermetic… Read More
  • Types of a relay Three types of relay :-  Current coil or amperage type relay Potential or voltage type relay. Hot wire relay.        … Read More
  • How to Identify Common / Start / Run on the t Compressor Terminal in 3 easy steps use the formula: - 1. common and start is equal to medium value 2. start and running is equal to high value 3.… Read More
  • RETROFITTING OF R 22 MACHINE WITH R427 A For retrofitting of R 22 machine with R 427 A proceed as under : 1. Start the machine charged with R 22 and note its temperatures and pressures. See … Read More
Newer Post Older Post Home

0 comments:

Post a Comment

More Info

  • Refrigerant pressure readings R-22, R-410A, R-290, R-417A
    R-22 Standing pressure              -                150 PSI Saction pressure                -                 60 TO 70 PSI Discha...
  • Types of a relay
    Three types of relay :-  Current coil or amperage type relay Potential or voltage type relay. Hot wire relay.          Relay ? ...
  • How to Identify Common / Start / Run on the t Compressor Terminal
    in 3 easy steps use the formula: - 1. common and start is equal to medium value 2. start and running is equal to high...
  • What is the high side and low side of the refrigeration system?
    Q. What are the parts which divide the refrigeration system into low pressure side and high pressure side ?  Ans. Refrigerant c...
  • Formula for finding the piston displacement of a compressor
    Compressor can be calculated as follows:- Where:- V = Volume in cubic feet.  D = Diameter of cylinder in inches.  S = Length o...

Course Process

  • High side and Low side ?
  • Interview Questions
  • Lock Rotor Amps
  • Mechanical refrigeration
  • Refrigerant pressure readings
  • Refrigeration system
  • ServiceTool
  • Temperature-pressure
  • Voltage type relay
  • Wiring Diagram

Related Posts:

  • Gas charging ,R410A R22 R32 pressures, - HINDI
    This video is helping to know  identify the gas in the  air condition unit and what kinds of the pressure we will maintain to the ai...
  • Refrigerant pressure readings R-22, R-410A, R-290, R-417A
    R-22 Standing pressure              -                150 PSI Saction pressure                -                 60 TO 70 PSI Discha...
  • How to Identify Common / Start / Run on the t Compressor Terminal
    in 3 easy steps use the formula: - 1. common and start is equal to medium value 2. start and running is equal to high...
  • Formula for finding the piston displacement of a compressor
    Compressor can be calculated as follows:- Where:- V = Volume in cubic feet.  D = Diameter of cylinder in inches.  S = Length o...

Blog Archive

  • ►  2019 (1)
    • ►  January (1)
  • ▼  2018 (35)
    • ►  July (2)
    • ►  February (2)
    • ▼  January (31)
      • Rotary Compressors:-
      • Hermetic Compressors
      • Important Terms
      • How to wiring window air condition
      • Window air condition PCB board wiring
      • L R A ( Lock Rotor Amps ) HINDI
      • Gas charging ,R410A R22 R32 pressures, - HINDI
      • Formula for finding the piston displacement of a c...
      • LAWS OF REFRIGERATION
      • Float valve function
      • CONDENSER
      • Rotary Compressor main parts
      • Types of a Compressor
      • Lock Rotor Amps
      • Tube cutter
      • Voltage type relay work ?
      • Types of a relay
      • How to Identify Common / Start / Run on the t Comp...
      • RETROFITTING OF R 22 MACHINE WITH R427 A
      • R427 A
      • R410 A
      • Mechanical refrigeration system
      • FLOAT VALVE CONTROLS
      • CAPILLARY TUBE
      • THE CENTRAL AIR CONDITIONING PLANT
      • Split Air Conditioner Selection of place for insta...
      • Refrigeration system?
      • Ton AC sufficient foot room
      • Gas charging
      • Refrigerant pressure readings R-22, R-410A, R-290,...
      • What is R410a Refrigerant
  • ►  2017 (7)
    • ►  December (7)

ABOUT US

ABOUT US
Ramesh Kurup :- Hello friends welcome to our blog “ Bten aircool. This is Ramesh Kurup.I am a professional Air Conditioner technician. I work with Bten Aircool since 3 years. This company is located in Mumbai Maharashtra.

Featured post

Voltage type relay work ?

  • Privay Policy
  • Disclaimer
  • Contact Us

Copyright © 2025 BTEN AIRCOOL