Monday, 8 January 2018

Split Air Conditioner Selection of place for installation

 Btenaircool Services     January 08, 2018     No comments   

                                                                  Outdoor unit                                                                     

Split Air Conditioner Selection of place for installation 
  1.  It can be installed out side of the room to be air conditioned on its out side wall, floor or its roof. 
  2. It should be installed on such a place where it can find sufficient open air from all of its           surroundings. 
  3.  It is better to install under a roof where it can be saved from the direct rays of sun and showers of rain. 
  4.  It should be installed on a solid plain floor.
  5.  It should be installed away from a common path. 
  6. It should be installed at a minimum distance from the room to be air conditioned to minimize the use of pipe lines and quantity of refrigerant. 
  7. It should be installed on some height so that rain water may pass without harming it

        How to Install Split Air Conditioner - Hindi      




                                                                      In Door Unit                                                                   

  1.  It should be installed on a plain solid wall of an enclosed room to be air-conditioned.
  2. It should be installed near the outdoor unit, electrical connection and a place where its water can be drained out. 
  3.  It should be installed on a place in the wall where it can get or throw the air without any restriction.
  4.  It should be installed on the wall with a minimum distance of 300 mm from the ceiling and 125 mm from the left and right side walls.
  5.  It should be installed on the height of about 2.5 meters from the floor.
  6. The length of its suction line, liquid line and electric cable can be from 5 meters to 20 meters.
  7. Its height from the outdoor unit can be 2.5 meters- to 8 meters. 

          InstallatiOn Proceed as follow for the installation of Split Air Conidtioner.                  


  •  Remove the air filter and grill from the indoor unit.
  •  Place the installation plate of the indoor unit on the wall at proper place and mark the hole location of 6.5 mm di a for passing the liquid and suction line through it.
  •  Make the hole in the wall at the marked place with drill machine. 
  • Fix the installation plate of the indoor unit with screws, preferably with anchor bolts. 
  • Fix the evaporator on the installation plate.
  •  Connect the stabilizer with the wall socket near by.
  • Connect the indoor unit with stabilizer. 
  •  Fit the air filter and grill with indoor unit. 
  •  Place and fit the outdoor unit as shown in the figure.
  •  Measure and cut the length of liquid line, suction line and drain pipe. 
  • Make proper fitting of above said pipes and connect them properly at their proper places.
  • The out door unit is loaded with sufficient refrigerant to be charged. Purge this gas through indoor unit or draw vacuum in the indoor unit with vacuum pump before purging and after it, purge a little amount of gas and maintain a little pressuie in the indoor unit. 
  •  Check the gas leakage in the machine and repair the leak if any. 
  •  Release the full gas from the outdoor unit in the entire air conditioning system. 
  • Operate the machine and check its back pressure. 
  • Share This:  
  •  Facebook
  •  Twitter
  •  Google+
  •  Stumble
  •  Digg
Email ThisBlogThis!Share to XShare to Facebook

Related Posts:

  • Window air condition PCB board wiring Window air condition PCB board wiring this video is totally helpful for know the component of the PCB board and how the PCB board work we will d… Read More
  • Air conditioning problems We Take Care of all Air Conditioning Problems in Mumbai. We have more than 7 years experience of handling all types of air conditioning p… Read More
  • How to wiring window air condition How to wiring window air condition compressor , fan motor, to multi capacitor . we will discuss How to connect PCB board to compressor and f… Read More
  • Important Terms Suction pressure.  It is the absolute pressure of refrigerant at the inlet of a compressor.  Discharge pressure.  It is the absolute… Read More
  • L R A ( Lock Rotor Amps ) HINDI What is LRA?  We discuss about LRA  this is the most important to know what is the LRA and how we know the TON of the compressor So L… Read More
Newer Post Older Post Home

0 comments:

Post a Comment

More Info

  • Formula for finding the piston displacement of a compressor
    Compressor can be calculated as follows:- Where:- V = Volume in cubic feet.  D = Diameter of cylinder in inches.  S = Length o...
  • Training Air Conditioner csr wiring - HINDI (Air condenser repair and se...
  • High-Pressure Washer- Hindi
  • How to Clean and Flush Air Conditioner Hindi
  • Window air conditioner fan motor winding

Course Process

  • High side and Low side ?
  • Interview Questions
  • Lock Rotor Amps
  • Mechanical refrigeration
  • Refrigerant pressure readings
  • Refrigeration system
  • ServiceTool
  • Temperature-pressure
  • Voltage type relay
  • Wiring Diagram

Related Posts:

  • Gas charging ,R410A R22 R32 pressures, - HINDI
    This video is helping to know  identify the gas in the  air condition unit and what kinds of the pressure we will maintain to the ai...
  • Refrigerant pressure readings R-22, R-410A, R-290, R-417A
    R-22 Standing pressure              -                150 PSI Saction pressure                -                 60 TO 70 PSI Discha...
  • How to Identify Common / Start / Run on the t Compressor Terminal
    in 3 easy steps use the formula: - 1. common and start is equal to medium value 2. start and running is equal to high...
  • Formula for finding the piston displacement of a compressor
    Compressor can be calculated as follows:- Where:- V = Volume in cubic feet.  D = Diameter of cylinder in inches.  S = Length o...

Blog Archive

  • ►  2019 (1)
    • ►  January (1)
  • ▼  2018 (35)
    • ►  July (2)
    • ►  February (2)
    • ▼  January (31)
      • Rotary Compressors:-
      • Hermetic Compressors
      • Important Terms
      • How to wiring window air condition
      • Window air condition PCB board wiring
      • L R A ( Lock Rotor Amps ) HINDI
      • Gas charging ,R410A R22 R32 pressures, - HINDI
      • Formula for finding the piston displacement of a c...
      • LAWS OF REFRIGERATION
      • Float valve function
      • CONDENSER
      • Rotary Compressor main parts
      • Types of a Compressor
      • Lock Rotor Amps
      • Tube cutter
      • Voltage type relay work ?
      • Types of a relay
      • How to Identify Common / Start / Run on the t Comp...
      • RETROFITTING OF R 22 MACHINE WITH R427 A
      • R427 A
      • R410 A
      • Mechanical refrigeration system
      • FLOAT VALVE CONTROLS
      • CAPILLARY TUBE
      • THE CENTRAL AIR CONDITIONING PLANT
      • Split Air Conditioner Selection of place for insta...
      • Refrigeration system?
      • Ton AC sufficient foot room
      • Gas charging
      • Refrigerant pressure readings R-22, R-410A, R-290,...
      • What is R410a Refrigerant
  • ►  2017 (7)
    • ►  December (7)

ABOUT US

ABOUT US
Ramesh Kurup :- Hello friends welcome to our blog “ Bten aircool. This is Ramesh Kurup.I am a professional Air Conditioner technician. I work with Bten Aircool since 3 years. This company is located in Mumbai Maharashtra.

Featured post

Voltage type relay work ?

  • Privay Policy
  • Disclaimer
  • Contact Us

Copyright © 2025 BTEN AIRCOOL