What is the high side and low side of the refrigeration system?

 Btenaircool Services     December 28, 2017     No comments   

Q. What are the parts which divide the refrigeration system into low pressure side and high pressure side ?

 Ans. Refrigerant control device and Head plate of a reciprocating compressor or Dividing blade of a rotary compressor.

Q. What is the high side and low side of the refrigeration system?

 Ans. When refrigeration system is operated, two pressures are developed in the system. Those parts of mechanical refrigeration system in which the pressure of gas remains low, called the low pressure side and the parts in which pressure remains high, called the high pressure side of the system.




Q. List of main parts which belong to low side of the system.

1. Outlet of refrigerant control device.
2. Evaporator.
3. Accumulator.
4. Suction line.
5. Half portion of head plate and crank case of reciprocating compressor.

  • Share This:  
  •  Facebook
  •  Twitter
  •  Google+
  •  Stumble
  •  Digg
Email ThisBlogThis!Share to XShare to Facebook

Related Posts:

  • RETROFITTING OF R 22 MACHINE WITH R427 A For retrofitting of R 22 machine with R 427 A proceed as under : 1. Start the machine charged with R 22 and note its temperatures and pressures. See … Read More
  • R427 A This refrigerant has been prepared by mxing R32 +R125 + R143a + R134a in their mass percentages of 15 + 25 + 10 + 50 respectively. It belongs to HFC … Read More
  • FLOAT VALVE CONTROLS The float valve controls are of two types. One is low side float control and the other is high side float. This type of control is used in the floode… Read More
  • How to Identify Common / Start / Run on the t Compressor Terminal in 3 easy steps use the formula: - 1. common and start is equal to medium value 2. start and running is equal to high value 3.… Read More
  • Types of a relay Three types of relay :-  Current coil or amperage type relay Potential or voltage type relay. Hot wire relay.        … Read More
Newer Post Older Post Home

0 comments:

Post a Comment

More Info

  • Refrigerant pressure readings R-22, R-410A, R-290, R-417A
    R-22 Standing pressure              -                150 PSI Saction pressure                -                 60 TO 70 PSI Discha...
  • How to Identify Common / Start / Run on the t Compressor Terminal
    in 3 easy steps use the formula: - 1. common and start is equal to medium value 2. start and running is equal to high...
  • Types of a relay
    Three types of relay :-  Current coil or amperage type relay Potential or voltage type relay. Hot wire relay.          Relay ? ...
  • Rotary Compressors:-
    In rotary compressors, the vapour refrigerant from the evaporator is compressed due to the movement of blades. The rotary compressors are ...

Course Process

  • High side and Low side ?
  • Interview Questions
  • Lock Rotor Amps
  • Mechanical refrigeration
  • Refrigerant pressure readings
  • Refrigeration system
  • ServiceTool
  • Temperature-pressure
  • Voltage type relay
  • Wiring Diagram

Related Posts:

  • Gas charging ,R410A R22 R32 pressures, - HINDI
    This video is helping to know  identify the gas in the  air condition unit and what kinds of the pressure we will maintain to the ai...
  • Refrigerant pressure readings R-22, R-410A, R-290, R-417A
    R-22 Standing pressure              -                150 PSI Saction pressure                -                 60 TO 70 PSI Discha...
  • How to Identify Common / Start / Run on the t Compressor Terminal
    in 3 easy steps use the formula: - 1. common and start is equal to medium value 2. start and running is equal to high...
  • Formula for finding the piston displacement of a compressor
    Compressor can be calculated as follows:- Where:- V = Volume in cubic feet.  D = Diameter of cylinder in inches.  S = Length o...

Blog Archive

  • ►  2019 (1)
    • ►  January (1)
  • ►  2018 (35)
    • ►  July (2)
    • ►  February (2)
    • ►  January (31)
  • ▼  2017 (7)
    • ▼  December (7)
      • What is the high side and low side of the refriger...
      • Difference between mechanical system and Absorptio...
      • Ton Of Refrigeration - HINDI
      • What is the meaning of BTU in air conditioners?
      • Outdoor wiring diagram
      • Reasons for Choosing US
      • Air conditioning problems

ABOUT US

ABOUT US
Ramesh Kurup :- Hello friends welcome to our blog “ Bten aircool. This is Ramesh Kurup.I am a professional Air Conditioner technician. I work with Bten Aircool since 3 years. This company is located in Mumbai Maharashtra.

Featured post

Voltage type relay work ?

  • Privay Policy
  • Disclaimer
  • Contact Us

Copyright © 2025 BTEN AIRCOOL